---+!! Birmingham Irradiations ---++ Radiation safety Slides from training on 20 October 2017: [[%ATTACHURL%/safetytraining2017laura2.pdf][safetytraining2017laura2.pdf]] MC 40 local rules: [[%ATTACHURL%/local_rules_2016rev4.pdf][local_rules_2016rev4.pdf]] University of Birmingham radiation safety website: https://intranet.birmingham.ac.uk/hr/wellbeing/worksafe/radiation/index.aspx ---++++ Irradiations at Birmingham MC40 This page is meant to collect information to run irradiations at the MC40 cyclotron in Birmingham. The general procedure for the irradiations is: * <span style="background-color: transparent">sample preparation</span> * <span style="background-color: transparent">beam alignment</span> * <span style="background-color: transparent">sample installation</span> * <span style="background-color: transparent">cooling down</span> * <span style="background-color: transparent">irradiation</span> * <span style="background-color: transparent">warming up</span> * <span style="background-color: transparent">sample removal and storage</span> * <span style="background-color: transparent">offline dosimetry</span> * <span style="background-color: transparent">sample shipment (if applicable)</span> ---+++++ Sample preparation Bare sensors are embedded in two layers of kapton tape, one on the back and one on the front. The one on the back is used to stick to sensor to it. The one on the front should not have the sticky part on the sensor, to avoid glue residuals on the pads. Carbon frames with cut-outs are used to old the sensors in place. In case the sample to irradiate has wire bonds (typ. ASICs/module on PCB), a frame (3D printed or aluminium) is used to protect the wire bonds. The frame can be fixed with kapton tape. If the backside of the chip has no PCB layer underneath, put a layer of kapton to avoid scratches. Ni foils for dosimetry are positioned on top of the sample with kapton tape. Large Ni foils (i.e. k type) should be used for point-to-point irradiation. Once prepared the samples are mounted on aluminum frame for cooling and suspened from the box lid for irradiations. https://www.ep.ph.bham.ac.uk/twiki/pub/BILPA/BhamIrrad/Bare-Sensors-1.jpg https://www.ep.ph.bham.ac.uk/twiki/pub/BILPA/BhamIrrad/Bare-Sensors-2.jpg https://www.ep.ph.bham.ac.uk/twiki/pub/BILPA/BhamIrrad/ASIC-3DprintedFrame.jpg https://www.ep.ph.bham.ac.uk/twiki/pub/BILPA/BhamIrrad/ASIC-AlFrame-GafchrFilm.JPG ---+++++ Beam alignment Put the gafchromic film on the top left of the aluminum, i.e. where the beam home position is. Make sure that the gafchromic film is not over-exposed otherwise the beam spot will be much larger and the alignment will not be correct! After alignment is done, remove the gafchromic film and store it in the logbook. Refer to [[%ATTACHURL%/Scanning_notes.pdf][Scanning_notes.pdf]]. ---+++++ Instructions to operate the robot scanning system <font color="crimson"> *!!! IMPORTANT GENERAL REMARKS - PLEASE READ CAREFULLY !!!* </font> * <span style="background-color: transparent">Always start with the VI for parking and homing</span><span style="background-color: transparent"> </span> * <span style="background-color: transparent">When starting/running a VI, a window pops up. </span>When it says "deployment completed successfully" press "close" * When running an irradiation in scanning mode, the VI does not support "STOP" and if you abort the system will crash, so DO NOT STOP/ABORT a scan!!! * Before closing a VI, make sure it is stopped * Always leave the box in park position after irradiation * Do not save the project when closing it * If the PC is ON adn the motors and LabVIEW software are off, restart the PC before switching on the motors and the LabVIEW * If a problem arises contact Laura or Tony * Note down in the logbook the start and stop time of the irradiation, and the number of counts at the faraday cup with the scale. They are needed to calculate the fluence * With the new system, the fan now needs to be manually plugged in. There is a white plug that needs to be plugged into the white extension, that are both hanging from above the Norhof. The fan should come on straight away. * The Norhof also needs to be switched on via the plug on the wall. It is the switch on the right side of the right plug. The Norhof will beep several times to let you know that it is on. ---++++++ Start-up procedure * Switch ON right box, a green LED will light up when it is on * Wait 5-10 seconds * Switch ON left box, a green LED will light up when it is on * On the right box there is a second switch (just behind the one you pressed before). This needs to be switched on, and a blue LED will light up. * Switch ON the PC. Wait a couple of minutes that it finishes the connection to the network. It is very important that the connection to the network is established BEFORE starting LabVIEW. Check the network icon on the right end of the task bar. As long as there is a blue circle on it, do not open LabVIEW! * From the start menu or the task bar, start LabVIEW 2015 * Select the project called " *20181018_Full_System_Upgrade_08_PLB_Ben* " * Right click on the controller (i.e. NI_cRI09022-015E9E20) and press "Connect" * Expand the controller * Expand " *PLB New Pillar* " * Open " *20181018_Initialisation_PLB_00* ", you will know if it is the right VI if both the home and reference buttons are already greyed out. * Press run (i.e. the arrow on the left) * The program will now only let you press one button at a time, to avoid any bugs from occuring. This program will allow you to put the box into park followed by home; once it is in home, the program will stop. You can leave the box in park (after pressing the reference button) before homing, but the program will never stop this way. However, this is a useful feature to access the box to mount/remove the sample, or check the beam current in-between scans. If you need to solely park the box, read the "At the end of the irradiation" section. * With the box at home, check the values it gives of Yinit-Pillar and Xinit-Parker, and note them in the logbook. This is the home position! ---++++++ Irradiation in scanning mode * Put the box in the home position. This is very important because the next VI you open will need to get the values of Yinit-Pillar and Xinit-Pillar corresponding to the ones for the home position! * Open " *20181016_New Scan Parameters_PLB_03_B* " * Press run * Feed in the required values (current, increment, velocity, height and length of the sample area to be irradiated). * For the offsets, you need to measure the distance between the right side of the beam spot and the left side of the sample for the x offset, and between the bottom of the beam spot and the top of the sample for the y offset. You must then *subtract the x offset value from the x home coordinate*, and *add the y offset value to the y home coordinate* and input these into the x and y controls (below the graph), and then press the *Overwrite init pos?* button, which should turn green. You can refer to <span style="text-decoration-line: underline; color: #0000ff">[[%ATTACHURL%/Scanning_notes.pdf][Scanning_notes.pdf]]</span> to calculate the height, lenght and x-/y- offsets. Please remember to also note them down in the logbook * Press the Update button. This will also stop the VI * Look at the graph to check you have set up the right scan path. * Open " *20181016_NewScanPath_PLB_05* ". This VI controls the scan having read in parameters from the previous VI * Check that the scan is setup correctly and the system works fine: put an aluminium frame with gafchromic film in the box instead of the sample to irradiate, set the number of runs to 1, press run, and ask the operator to start the beam * If the correct area is scanned, put the sample in the box and input the correct number of runs in the program * Click the tick symbol (on upper bar) to properly input the value * Ask the operator to reset the number of counts at the faraday cup * Press run (arrow on upper bar) and press the close button (on the window that appears) at the same time as the operator switches the beam on (use a countdown to make sure you both press at the same time) * If you want to have an estimate of the time needed for a scanning irradiation you can use this spreadsheet:<span style="color: #0000ff; text-decoration: underline">[[%ATTACHURL%/Scanning-Irrad-Time-Calc-Jan-18.xlsx][Scanning-Irrad-Time-Calc-Jan-18.xlsx]]</span> * With the new system, you can now stop the scan midway, if needed (the beam disappears, the box robot isn't woking properly, etc.) * On the " *20181016_NewScanPath_PLB_05* " VI, press the stop button. The box will not stop immediately, but instead travel to the end of the row that it was just scanning, and then stop * Once it has stopped, you will need to reference (park) the box so that the system knows where the box is. You can either do this through " *20181018_Initialisation_PLB_00* " or " *20181016_Referencing_Only_PLB_00* " * If the box does not move, you will need to go through the procedure of switching the boxes off and then back on again. ---++++++ Irradiation in point-to-point mode * To calculate the time of the irradiation to get to the target fluence use the spreadsheet <span style="color: #0000ff; text-decoration: underline">[[%ATTACHURL%/Fluence-TID-Jan-18-lg.xlsx][Fluence-TID-Jan-18-lg.xlsx]]</span> * You need to add 20% more time to account for beam inhomogeneity * For a point to point irradiation, your set up is the same as scanning, up to and including connecting to the controller (NI....) * From there you will need to expand *New Manual* * Open " *20180806_Imran_XY_ManualController.vi* " * Insert the home coordinates as the first location * Run the program to put the box at home * Ping the veam to get the beam spot at the home location on the gafchromic film * You will then need to meausre the x and y offsets between the home location and the sample to be irradiated. Whilst doing this, remember to measure to and from the same spot on the beam (i.e. measure from the right side of the beam to where you want the right side of the beam to be on the sample) * You must then add/subtract the measurement to the home coordinates. For the *x offset you must subtract the x offset from the home x coordinate*, and for the *y offset you must add the y offset to the home y coordinate* * <span style="background-color: transparent">Click the tick symbol (on upper bar) to properly input the values</span> * <span style="background-color: transparent">To test that these locations are correct, you can use the gafchromic film and ping the beam at each location</span> * When moving to the next location, you will need to press next x location and next y location buttons in turn. You must wait for the box to stop moving before you press the next button ---++++++ At the end of the irradiation (after warming up the sample) * <span style="background-color: transparent">Once you have finished your irradiation, you should park the box. You cannot use the Initialisation VI to do this; you must use " *20181016_Referencing_Only_PLB_00* "</span> * <span style="background-color: transparent">Run this program</span> * <span style="background-color: transparent">Press Start Referencing</span> * <span style="background-color: transparent">This VI will stop by itself, but it takes a few seconds after the box has stopped moving.</span> * <span style="background-color: transparent">Once you have parked the box and the VI has stopped, you can now close all the VIs that you opened</span> * <span style="background-color: transparent">You must then disconnect by right clicking the controller again (NI....)</span> * <span style="background-color: transparent">Close the project. </span>%RED% *DO NOT SAVE!!!* %ENDCOLOR% * <span style="background-color: transparent">Close LabVIEW</span> * <span style="background-color: transparent">Switch off the *left box* </span> * <span style="background-color: transparent">Wait 5-10sec</span> * <span style="background-color: transparent">Switch off the *right box* </span> * <span style="background-color: transparent">Switch off the PC</span> * <span style="background-color: transparent"><strong><u>Remember to unplug the fan and switch off the Norhof when it is safe to enter the area!!!</u></strong></span> ---+++++ Cooling down and warming up procedures (i.e. operation of the Norhof system) * Start the Arduino system (see instructions below) * Make sure the box is sealed with tape! * Make sure the fan is ON * Flush N2 for approx. 30 minutes (or until the RH reading on the Arduino is stable around 10-15%) before starting cooling * Lauch the two Norhof programs from the icon on the desktop. They are called "NorhofPumpDrive" and "NorhofPumpMonitor" * In "NorhofPumpDrive", set the RS232 Control to 1 and press "set" * In the "NorhofPumpMonitor" window you should see that the flow has started * Once the temperature is stable at the target values, switch off the N2. The fan stays ON * At the end of the irradiation, switch off the Norhof. <span style="background-color: transparent">In "NorhofPumpDrive", set the RS232 Control to 0 and press "set". Leave the fan ON and start again the N2.</span> * When the temperature is at the target value, switch off the fan and the Norhof (switch on right box), and the N2 ---+++++ Arduino system to monitor temperature and humidity * <span style="background-color: transparent">Start "gobetwino" (link on desktop). The numbers for the temperature and humidity sensor should start to be dislayed and updated</span> * <span style="background-color: transparent">Open Livegraph.20.beta01.Complete (link on desktop). A few windows pop up. You can minimize all but the one showing the graph</span> * <span style="background-color: transparent">Go to the folder called "TempHum". Make a copy of the file called "LogArduino.txt" and rename it with the current date and time. Then delete the content of the file </span>"LogArduino.txt" and save the empty file. Now the Livegrpah plot will show only the new data * In total there are 3 temperature sensors and 2 humidity sensors, called t1, t1a, t2, and h1 and h2. The value shown need to be divided by 100. * <span style="background-color: transparent">If not all temperature and humidity measurements are shown in the plot, go to the window called "Data series settings (</span>LiveGraph<span style="background-color: transparent">)" and select the number below the corresponding name (i.e. below t1, t1a, t2, h1, h2)</span> ---+++++ Dosimetry with Ni foils * <span style="background-color: transparent">The spectrum of the nickel foil is measured using the "Maestro" program</span> * <span style="background-color: transparent">The two peaks at 511keV and 1377keV are measured</span> * <span style="background-color: transparent">The measured activity can be fed into the spreadsheet to calculate the fluence: </span><span style="color: #0000ff; text-decoration: underline">[[%ATTACHURL%/new_Ni_11l_1318_17Feb2016.xlsx][new_Ni_May16-lg.xlsx]]</span> * The weight of the nickel foils can be found here: <span style="color: #0000ff; text-decoration: underline">[[%ATTACHURL%/Ni-foils-L-weight.pdf][Ni-foils-L-weight.pdf]], [[%ATTACHURL%/Ni-foils-K-weight.pdf][Ni-foils-K-weight.pdf]], </span><span style="caret-color: #0000ff; color: #0000ff; text-decoration: underline">[[%ATTACHURL%/Ni-folis-Z-weight.pdf][Ni-folis-Z-weight.pdf]]</span>, [[%ATTACHURL%/Ni_foils_K_17-32_weight.pdf][Ni_foils_K_17-32_weight.pdf]] ---+++++ Sample removal and storage ---+++++ Shipment of samples * <span style="background-color: transparent">Ask David Clifford to check that the sample is safe to be shipped as non-radioactive</span> * <span style="background-color: transparent">Samples should be shipped cold, in a polystyrene box with ice blocks. These can be found in PB8 </span> * <span style="background-color: transparent">The shipment type should selected to arrive at destination within one day to avoid warming up of the samples</span> * <span style="background-color: transparent">Do not ship samples on Friday, as they will arrive at destination on Saturday and will not be picked up by Monday. By then all the ice will have melt and they will be at room temperature!</span> * <span style="background-color: transparent">Please use the following instructions to create the shipment: within the EU </span><span style="color: #0000ff; text-decoration: underline">[[%ATTACHURL%/Shipment-Instructions.pdf][Shipment instructions]]</span>, outisde the EU <span style="color: #0000ff; text-decoration: underline">[[%ATTACHURL%/Shipment-Instructions-OutsideEU.pdf][Shipment instructions outside the EU]]</span> * <span style="background-color: transparent">Once the shipment is ready it can be left at stores for collection, or brought to post room so they can check that everything is OK</span> ---+++++ Useful documents and links * Point-to-point irradiation: spreadsheet to calculate the time needed to reach the target fluence or TID: <span style="color: #0000ff; text-decoration: underline">[[%ATTACHURL%/Fluence-TID-Jan-18-lg.xlsx][Fluence-TID-Jan-18-lg.xlsx]]</span> * Scanning irradiation: spreadsheet to calculate the time the irradiaiton will take: <span style="color: #0000ff; text-decoration: underline; background-color: transparent">[[%ATTACHURL%/Scanning-Irrad-Time-Calc-Jan-18.xlsx][Scanning-Irrad-Time-Calc-Jan-18.xlsx]]</span> * Spreadsheet to calculate fluence from spectrum of Ni foil: <span style="color: #0000ff; text-decoration: underline">[[%ATTACHURL%/new_Ni_11l_1318_17Feb2016.xlsx][new_Ni_May16-lg.xlsx]]</span> * Spreadsheet to calculate fluence from spectrum of Ni foil (with error propagation): <span style="color: #0000ff; text-decoration: underline"> [[%ATTACHURL%/Ni_11_ErrorPropagation.ods][Ni_11_ErrorPropagation.ods]]</span> * <span style="background-color: transparent">Weight of Nickel foils: </span>[[%ATTACHURL%/Ni-foils-L-weight.pdf][Ni-foils-L-weight.pdf]]<span style="color: #0000ff; text-decoration: underline">, </span>[[%ATTACHURL%/Ni-foils-K-weight.pdf][Ni-foils-K-weight.pdf]], <span style="color: blue; text-decoration: underline; background-color: transparent">[[%ATTACHURL%/Ni-folis-Z-weight.pdf][Ni-folis-Z-weight.pdf]], [[%ATTACHURL%/Ni_foils_K_17-32_weight.pdf][Ni_foils_K_17-32_weight.pdf]]</span> * <span style="background-color: transparent">Notes on scanning from John (6th Jan 2016): </span><span style="color: #0000ff; text-decoration: underline">[[%ATTACHURL%/Scanning_notes.pdf][Scanning_notes.pdf]]</span><span style="background-color: transparent"> NB: Instructions in appendix 1 and 2 are outdated. Follow the instructions on this page.</span> * <span style="background-color: transparent">Notes on TID at cyclotron from John (10th Mar 2015): </span>[[%ATTACHURL%/TID_at_cyclotron.pdf][TID_at_cyclotron.pdf]] * <span style="background-color: transparent">Notes on humidity tests from John (26th Sept 2015): </span>[[%ATTACHURL%/humidity_tests.pdf][humidity_tests.pdf]] * Shipment instructions within the EU: [[%ATTACHURL%/Shipment-Instructions.pdf][Shipment instructions]] * Shipment instructions outside the EU: <span style="color: #0000ff; text-decoration: underline">[[%ATTACHURL%/Shipment-Instructions-OutsideEU.pdf][Shipment instructions outside the EU]]</span> * RD50 page [[http://rd50.web.cern.ch][RD50]] * <span style="background-color: transparent">Cross section for 28-Ni-0(P,X)28-NI-57: </span><span style="color: #0000ff; text-decoration: underline">[[%ATTACHURL%/X4Servlet_Select.pdf][X4Servlet_Select.pdf]], </span><span style="color: #0000ff; text-decoration: underline">[[%ATTACHURL%/X4R1150_x4.zvd.dat.webarchive][X4R1150_x4.zvd.dat.webarchive]]</span> * <span style="background-color: transparent">Talk from James at ITk week Sept. 2015: </span>[[%ATTACHURL%/RadResultsNew.pdf][RadResultsNew.pdf]] * <span style="background-color: transparent">Links to papers on facility: </span><span style="color: #0000ff; text-decoration: underline">[[http://www.sciencedirect.com/science/article/pii/S0168900213007675][The Birmingham Irradiation Facility (Dec 2013)]], </span>[[http://www.sciencedirect.com/science/article/pii/S0168900215001734][Upgrade to the Birmingham Irradiation Facility (oct 2015)]],[[http://iopscience.iop.org/article/10.1088/1748-0221/12/03/C03075][<span style="background-color: transparent; color: blue; text-decoration: underline">Recent results and experience with the Birmingham MC40 irradiation facility</span><span style="color: blue; background-color: transparent">]]</span> %STOPINCLUDE% -- Main.LauraGonella - 26 Apr 2016
Attachments
Attachments
Topic attachments
I
Attachment
History
Action
Size
Date
Who
Comment
pdf
X4Servlet_Select.pdf
r1
manage
157.9 K
13 May 2016 - 17:07
UnknownUser
webarchive
X4R1150_x4.zvd.dat.webarchive
r1
manage
48.2 K
13 May 2016 - 17:08
UnknownUser
pdf
TID_at_cyclotron.pdf
r1
manage
110.9 K
05 May 2016 - 12:06
UnknownUser
xlsx
Scanning-Irrad-Time-Calc-Jan-18.xlsx
r1
manage
13.2 K
31 Jan 2018 - 17:51
UnknownUser
pdf
Scanning_notes.pdf
r1
manage
269.6 K
07 Apr 2016 - 14:49
UnknownUser
pdf
safetytraining2017laura2.pdf
r1
manage
2444.9 K
20 Oct 2017 - 14:52
UnknownUser
pdf
RadResultsNew.pdf
r1
manage
3758.4 K
15 May 2016 - 17:04
UnknownUser
pdf
Ni-folis-Z-weight.pdf
r1
manage
67.8 K
07 Jun 2018 - 13:48
UnknownUser
pdf
Ni-foils-L-weight.pdf
r1
manage
46.2 K
07 Apr 2016 - 15:54
UnknownUser
pdf
Ni-foils-K-weight.pdf
r1
manage
30.0 K
07 Apr 2016 - 15:54
UnknownUser
pdf
Ni_foils_K_17-32_weight.pdf
r1
manage
112.7 K
07 Jun 2018 - 14:41
UnknownUser
ods
Ni_11_ErrorPropagation.ods
r1
manage
19.3 K
01 Dec 2017 - 13:33
UnknownUser
xlsx
new_Ni_11l_1318_17Feb2016.xlsx
r6
r5
r4
r3
r2
manage
15.2 K
20 May 2016 - 12:18
UnknownUser
pdf
local_rules_2016rev4.pdf
r1
manage
150.5 K
22 Feb 2018 - 16:14
UnknownUser
pdf
humidity_tests.pdf
r1
manage
523.9 K
05 May 2016 - 12:06
UnknownUser
xlsx
Fluence-TID-Jan-18-lg.xlsx
r1
manage
45.7 K
31 Jan 2018 - 17:49
UnknownUser
jpg
Bare-Sensors-2.jpg
r1
manage
203.7 K
22 Jul 2016 - 14:44
UnknownUser
jpg
Bare-Sensors-1.jpg
r1
manage
223.7 K
22 Jul 2016 - 14:43
UnknownUser
jpg
ASIC-AlFrame-GafchrFilm.JPG
r1
manage
207.0 K
22 Jul 2016 - 14:43
UnknownUser
jpg
ASIC-3DprintedFrame.jpg
r1
manage
164.7 K
22 Jul 2016 - 14:42
UnknownUser
This topic: BILPA
>
BhamIrrad
Topic revision: r37 - 24 Jan 2019 - huntera
Copyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki?
Send feedback